Concept List¶
This book's learning graph has 581 concepts. The number is the ConceptID used in learning-graph.csv.
- Air Movement
- Fan Speed
- Horsepower
- Airflow Volume
- Cubic Feet Per Minute
- Air Velocity
- Feet Per Minute
- Air Pressure
- Inches of Water Gauge
- Static Pressure
- Velocity Pressure
- Total Pressure
- Air Density
- Air Temperature
- Altitude
- Standard Air
- Airstream
- Contaminated Airstream
- Corrosive Airstream
- Particulate-Laden Airstream
- Hot Airstream
- Wet Airstream
- Explosive Atmosphere
- Duct System
- Fan
- Blower
- Fan Housing
- Impeller
- Fan Inlet
- Fan Outlet
- Fan Shaft
- Bearing
- Fan Motor
- Drive Train
- Fan Family
- Centrifugal Fan
- Axial Fan
- Mixed Flow Fan
- Scroll Housing
- Housed Centrifugal Fan
- Unhoused Centrifugal Fan
- Plenum Fan
- Plug Fan
- Inline Centrifugal Fan
- Square Inline Centrifugal Fan
- Tubular Housing
- Tubeaxial Fan
- Guide Vanes
- Vaneaxial Fan
- Panel Fan
- Ring Fan
- Pressure Blower
- Radial Bladed Fan
- Radial Tip Fan
- Duct Fan
- Filtered Supply Fan
- Power Roof Ventilator
- Roof Ventilator
- Centrifugal Roof Exhauster
- Centrifugal Wall Exhauster
- Roof Mounted Axial Fan
- Wall Mounted Fan
- Gravity Relief Ventilator
- Ceiling Ventilator
- Cabinet Ventilator
- Utility Set
- Laboratory Fume Exhaust Fan
- Kitchen Exhaust Fan
- Smoke and Heat Exhaust Fan
- Fiberglass Fan
- Mancooler
- Air Kit
- Commercial Duty Fan
- Industrial Duty Fan
- Upblast Discharge
- Downblast Discharge
- Entrained Flow
- Plume Dilution
- Nozzle and Windband
- Bypass Air Plenum
- Exploded View
- Housing Side Plate
- Scroll Wrapper
- Cutoff
- Inlet Collar
- Inlet Flange
- Outlet Flange
- Access Door
- Belt Guard
- Belt Tube
- Straightening Vanes
- Welded Housing
- Bolted Housing
- Weatherhood
- Backdraft Damper
- Bird and Safety Screens
- Roof Curb
- Stack Cap
- Split Housing
- Horizontal Split Housing
- Three-Way Split Housing
- Pie Split Housing
- Impeller Blade
- Blade Leading Edge
- Impeller Back Plate
- Impeller Shroud
- Impeller Hub
- Centrifugal Impeller
- Single Width Single Inlet
- Double Width Double Inlet
- Backward Inclined Impeller
- Backward Curved Impeller
- Airfoil Impeller
- Forward Curved Impeller
- Radial Bladed Impeller
- Radial Tip Impeller
- Material Handling Impeller
- Paper Handling Impeller
- Mixed Flow Impeller
- Axial Impeller
- Fixed Pitch Impeller
- Adjustable Pitch Impeller
- Fiberglass Axial Impeller
- Impeller Orientation
- Hub on Intake Side
- Hub on Discharge Side
- Reversible Impeller
- Straight Bore Hub
- Taper Lock Hub
- Reverse Bore Hub
- Back Plate Fins
- Impeller Balancing
- Direct Drive
- Belt Drive
- Sheave
- V-Belt
- Drive Service Factor
- Shaft Coupling
- Overhung Impeller
- Center Hung Impeller
- Fan Arrangement
- Arrangement 1
- Arrangement 2
- Arrangement 3
- Arrangement 3 SI and DI
- Arrangement 4
- Arrangement 7
- Arrangement 8
- Arrangement 9
- Arrangement 10
- Plug Fan Arrangements
- Arrangement 1P Plug
- Arrangement 4P Plug
- Plenum Fan Arrangements
- Vertical Arrangement
- Axial and Inline Arrangements
- Lab Exhaust Arrangements
- Swingout Fan
- Clamshell Fan
- Bearings Out of Airstream
- Viewed From Drive Side
- Rotation
- Clockwise Rotation
- Counterclockwise Rotation
- Rotation Arrow
- Discharge Position
- Discharge Angle
- Up Blast Discharge Position
- Top Horizontal Discharge
- Bottom Horizontal Discharge
- Down Blast Discharge Position
- Angular Discharge
- Rotation and Discharge Code
- DWDI Discharge Limits
- Axial Rotation Convention
- Inline Configuration
- Motor Position
- Motor Positions W X Y Z
- Motor Position Restrictions
- Axial Motor Positions
- Plenum Motor Positions
- Conduit Box Position
- Inlet Box Position
- Induction Motor
- EC Motor
- NEMA Frame Size
- Motor Enclosure
- ODP Motor
- TEFC Motor
- TEAO Motor
- TENV Motor
- Explosion Proof Motor
- Motor Service Factor
- Insulation Class
- Motor Efficiency Class
- Conduit Box
- C-Face Motor Mount
- Foot Mounted Motor
- Shaft Grounding Ring
- Motor Winding RTD
- Variable Frequency Drive
- Motor Base
- Slide Base
- Pivot Motor Base
- Motor Positioner
- Bi-Directional Positioner
- Tri-Directional Positioner
- Vertical Jack Screws
- Bearing Life
- L-10 Bearing Life
- L-50 Bearing Life
- Ball Bearing
- Spherical Roller Bearing
- Pillow Block Bearing
- Split Pillow Block Bearing
- Flange Mount Bearing
- Totally Split Roller Bearing
- Two-Bearing Housing
- Set Screw Mount
- Adapter Sleeve Mount
- Fixed Bearing
- Floating Bearing
- Bearing Lubrication
- Grease Fitting
- Static Oil Lubrication
- Oil Mist Lubrication
- Bearing Seal
- Labyrinth Seal
- Taconite Seal
- Bearing Positioner
- Bearing Stop Blocks
- Bearing Dowel Pins
- Bearing Vibration Sensor
- Restrained Bearing
- Shaft Keyway
- Shaft Turndown
- Shaft Sleeve
- Clad Shaft
- Shaft Locking Collar
- Fan Pedestal
- Separated Pedestal
- Shaft Seal
- Lip Shaft Seal
- Friction Shaft Seal
- Carbon Ring Seal
- Stuffing Box Seal
- Gas Purge Seal
- Inlet Funnel
- Inlet Venturi
- Inlet Box
- Integral Inlet Box
- Detached Inlet Box
- Free-Standing Inlet Box
- Evasé
- Transition Piece
- Companion Flange
- Flexible Connector
- Tube Adapter and Sleeve
- Inlet Silencer
- Outlet Silencer
- Flow Control
- Damper
- Parallel Blade Damper
- Opposed Blade Damper
- Outlet Damper
- Inlet Box Damper
- Gravity Damper
- Manual Damper
- Motorized Damper
- Blast Gate
- Slide Gate Damper
- Variable Inlet Vanes
- Pre-Spin
- Nested Inlet Vanes
- External Inlet Vanes
- Speed Control
- Turndown
- Construction Class
- Construction Material
- Stainless Steel Construction
- Aluminum Construction
- Coatings
- Spark Resistant Construction
- Non-Ferrous Material
- Spark Resistant Type A
- Spark Resistant Type B
- Spark Resistant Type C
- Rub Ring
- Rub Plate
- Fan Grounding Device
- High Temperature Construction
- Maximum Operating Temperature
- Shaft Cooler
- Heat Shield
- High Temperature Pedestal
- Thermal Expansion
- Insulated Fan
- Double Wall Construction
- Insulated Jacket
- Nominally Leak-Tight Fan
- Fan Leakage
- Gasketing
- Soap Bubble Test
- Regenerative Thermal Oxidizer
- High Moisture Construction
- Housing Drain
- Weep Hole
- Flue Gas Recirculation
- Fan Installation
- Fan Base
- Unitary Base
- Isolation Base
- Inertia Base
- Vibration
- Vibration Isolation
- Isolator Deflection
- Neoprene Isolation Pad
- Rubber-in-Shear Isolator
- Spring Isolator
- Floor Mounted Isolation
- Ceiling Hung Isolation
- Seismic Restraint
- Snubber
- Thrust Restraint
- Anti-Backspin Device
- Zero Speed Switch
- Piezometer Ring
- Airflow Measurement
- Pressure Transmitter
- Weather Cover
- Fan Performance
- Brake Horsepower
- Outlet Velocity
- Tip Speed
- Fan Static Pressure
- Fan Total Pressure
- Fan Efficiency
- Static Efficiency
- Peak Efficiency
- Fan Curve
- System Resistance
- System Curve
- Operating Point
- Duty Point
- Stall Region
- Surge
- Non-Overloading Power Curve
- Overloading Power Curve
- Fan Laws
- Speed Change Calculation
- Size Change Calculation
- Power Varies With Speed Cubed
- Density Correction Factor
- Temperature Correction
- Altitude Correction
- Fan Sound
- Sound Power Level
- Sone Rating
- Fan Class
- Maximum Safe Speed
- System Effect
- Fan Selection Range
- Flow Control Efficiency
- Fan Size
- Model Code
- Product Catalog
- AMCA Certified Ratings
- Performance Table
- Reading a Performance Table
- Interpolation
- Catalog Operating Limits
- Technical Description
- FanPedia vs Current Catalog
- Product Options
- Accessory Selection
- Motor Selection
- Drive Selection
- Fan Family Selection
- Impeller Selection
- Arrangement Selection
- Construction Selection
- Fan Selection
- Selection Trade-Offs
- Fan Selection Checklist
- Complete Fan Description
- Fan Specification
- Specification Review
- Fan Comparison
- Annotated Fan Drawing
- Capstone Fan Specification
- Pressure Rise
- Air Power
- Airflow Continuity Equation
- Velocity Pressure Equation
- Barometric Pressure
- Fan Outlet Area
- Outlet Velocity Pressure
- Fan Power Equation
- Efficiency Curve
- Peak Pressure Point
- Free Delivery
- Shutoff Pressure
- Fans in Parallel
- Fans in Series
- Pressure Varies as Speed Squared
- Specific Speed
- Cold Start Horsepower
- AMCA 210 Rating Standard
- AMCA Installation Type
- Inlet System Effect
- Outlet System Effect
- Effective Duct Length
- System Effect Curve
- Decibel
- Sound Pressure Level
- Octave Band
- Blade Pass Frequency
- Fan Energy Index
- Hooded Roof Exhauster
- Louvered Roof Exhauster
- Low Profile Roof Ventilator
- Roof Mounted Panel Fan
- Paint Booth Exhaust Fan
- Dust Collection Fan
- High Efficiency Centrifugal Fan
- Inline Lab Exhaust Fan
- Bypass Flow
- Lab Exhaust Total Flow
- Wiper Bar
- Housing Framing
- Bearing Structural Support
- Setback Outlet Flange
- Cast Housing
- Inspection Port
- Motor Support Base
- Motor Base Saddle
- Discharge Cone
- Housing Access Panel
- Mounting Panel
- Insulation Plug
- Motor Cover
- Roof Exhauster Shroud
- Curb Cap
- Relieved Inlet Transition
- Impeller Airflow Path
- Impeller Width
- Impeller Material
- Impeller End Ring
- Impeller Tie Rod
- Impeller Gusset
- Open Radial Paddle Impeller
- Air Handling Impeller
- Axial Blade Tip
- Axial Blade Count
- Blade Pitch Angle
- Fiberglass Hub
- Trantorque Hub
- Axial Fan Configuration
- Arrangement 3F
- Arrangement 4S Swingout
- Arrangement 4VI and 4HI
- Arrangement 7SI and 7DI
- Arrangement 9F
- Arrangement 9H
- Arrangement 9ST and 9SS
- Ventilating Set
- Arrangement 8P and 9P Plug
- Plenum Arrangements 3HS and 3HA
- Plenum Arrangement 3SM
- Plenum Arrangements 3VA and 3VS
- Plenum Arrangement 4V
- Arrangement 4CS and 9CS
- Arrangement 4SO and 9SO
- Top Angular Up Discharge
- Top Angular Down Discharge
- Bottom Angular Down Discharge
- Bottom Angular Up Discharge
- Inline Horizontal Configuration
- Inline Vertical Configuration
- Motor Positions L and R
- Standard Motor Position Rule
- Swingout Motor Position Rule
- K Mount Motor
- Inline Motor Positions A to H
- Vertical Inline Motor Location
- Motor Nameplate
- Motor Intended Duty
- Severe Duty Motor
- Hazardous Location Motor
- Premium Efficiency Motor
- Motor Voltage and Phase
- Synchronous Motor Speed
- Motor Temperature Rise
- Motor Thermal Protection
- Inverter-Duty Motor
- EC Motor Speed Controller
- Solid Pillow Block Bearing
- Concentric Bearing Mount
- Drive End Bearing
- Non-Drive End Bearing
- Two and Four Hole Mount
- Fixed-Floating Bearing Rules
- Bearing Seal Speed Limit
- Bearing RTD and Thermocouple
- High Expansion Bearing
- Damper and Vane Bearings
- Insulated Bearing
- Shaft Material Grades
- Forged Shaft
- Keystock
- Shaft and Coupling Guards
- Bolt-On Pedestal
- Isolator Mounting Method
- Direct Mounted Isolators
- Isolation Rails
- Isolator Mounting Angle
- Open Spring Isolator
- Housed Spring Isolator
- Restrained Spring Isolator
- Seismic Spring Isolator
- Internally Isolated Fan
- Shaft and Coupling Alignment
- Post Mount Motor Base
- Butterfly Gravity Damper
- Ceiling Type Gravity Damper
- Wall Type Gravity Damper
- Blade Flutter
- Damper Actuator
- Flat Blade Damper
- Airfoil Blade Damper
- Damper Throttling
- Lab Exhaust Isolation Damper
- Lab Exhaust Bypass Damper
- Inlet Box Horn
- Bolt-On Inlet Box
- Bolted Flange Connection
- Slip Connection
- Inlet Box Mounting Planes
- Insulated Inlet Box
- ASA Pipe Flange Bolt Pattern
- High Temperature Package
- Axial High Temperature Package
- High Temperature Grease
- Cooler Guard
- Cooler Box
- Insulation Pins
- Aluminum Clad Construction
- Recess Cone
- Corten Steel
- Buffer Strip
- Continuous Seal Weld
- Centering Plate
- RTO Service Conditions
- Swingout Door Assembly
- Double Door Clamshell
- Catalog Structure
- Fan Selector Software
- Performance Table Header
- Class Shading in Tables
- Rating Conditions
- Transmission Losses
- Appurtenance Effects
- Actual Operating Conditions
- Cold Start Motor Sizing
- Fan Efficiency Grade
- Octave Band Sound Data
- Dimensional Data Table
- Certified Drawings
- Material Specifications Table
- Airstream Conditions
- Air Change Method
- Minimum Conveying Velocity
- Space Constraints
- Noise Limits
- Efficiency Requirements
- Application Requirements
- CSI Format Specification
- Specification Performance Clause
- AMCA 204 Balance Grade
- First Critical Speed
- Submittal Data